DocumentCode :
1182796
Title :
Calibrating a VANA with a slightly lossy beadless coaxial standard line
Author :
Griffin, E.J.
Author_Institution :
RF & Microwave Guided-Wave Stand. Branch, Nat. Phys. lab., Malvern
Volume :
30
Issue :
19
fYear :
1994
fDate :
9/15/1994 12:00:00 AM
Firstpage :
1608
Lastpage :
1609
Abstract :
Use of a beadless coaxial standard line to calibrate a vector-indicating automatic network analyser (VANA) provides for measurement of the voltage reflection coefficient Γ in terms of the mode propagated by that line. Owing to skin effects, the impedance Z m assigned to that mode differs from that defined for an ideal lossless line of appropriate dimensions, Zdef(=50Ω). The author reports results of expressing the measured Γ in terms of the nominal Zdef for f⩾0.05 GHz, after accounting for the conductor loss by measurements with a type N beadless coaxial standard line
Keywords :
automatic test equipment; calibration; coaxial cables; measurement standards; microwave reflectometry; network analysers; skin effect; 0.05 GHz; VANA; calibration; conductor loss; impedance; mode propagation; skin effects; type N beadless coaxial standard line; vector-indicating automatic network analyser; voltage reflection coefficient measurement;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:19941105
Filename :
326358
Link To Document :
بازگشت