• DocumentCode
    1182796
  • Title

    Calibrating a VANA with a slightly lossy beadless coaxial standard line

  • Author

    Griffin, E.J.

  • Author_Institution
    RF & Microwave Guided-Wave Stand. Branch, Nat. Phys. lab., Malvern
  • Volume
    30
  • Issue
    19
  • fYear
    1994
  • fDate
    9/15/1994 12:00:00 AM
  • Firstpage
    1608
  • Lastpage
    1609
  • Abstract
    Use of a beadless coaxial standard line to calibrate a vector-indicating automatic network analyser (VANA) provides for measurement of the voltage reflection coefficient Γ in terms of the mode propagated by that line. Owing to skin effects, the impedance Z m assigned to that mode differs from that defined for an ideal lossless line of appropriate dimensions, Zdef(=50Ω). The author reports results of expressing the measured Γ in terms of the nominal Zdef for f⩾0.05 GHz, after accounting for the conductor loss by measurements with a type N beadless coaxial standard line
  • Keywords
    automatic test equipment; calibration; coaxial cables; measurement standards; microwave reflectometry; network analysers; skin effect; 0.05 GHz; VANA; calibration; conductor loss; impedance; mode propagation; skin effects; type N beadless coaxial standard line; vector-indicating automatic network analyser; voltage reflection coefficient measurement;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19941105
  • Filename