• DocumentCode
    1183778
  • Title

    Experimental Study on Cooling of Rotor in a Salient 4-Pole Synchronous Machine

  • Author

    Nonaka, S. ; Murata, K. ; Yamamoto, M. ; Takeda, Y.

  • Author_Institution
    Tokyo Shibaura Electric Co., Ltd.
  • Issue
    1
  • fYear
    1979
  • Firstpage
    310
  • Lastpage
    317
  • Abstract
    In case of the salient pole synchronous machine, coil brackets are usually placed between poles to support the rotor winding against centrifugal force. In general, four brackets are arranged along the axial direction of the pole for the foui pole machine in view of both the rigidity of the rotor winding and the centrifugal force. In addition, the number of brackets used has to be determined considering the gas flow and the coil temperature distribution between poles.
  • Keywords
    Coils; Cooling; Fluid flow; Machine windings; Stator windings; Synchronous machines; Temperature distribution; Temperature measurement; Testing; Ventilation;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1979.319533
  • Filename
    4113479