DocumentCode
118424
Title
Comparison of DTC and FOC for FSTP inverter fed IPMSM drives
Author
Ahmed, Toufik ; Das, Aruneema ; Halder, Kalyan Kumar
Author_Institution
Dept. of Electr. & Electron. Eng., Khulna Univ. of Eng. & Technol., Khulna, Bangladesh
fYear
2014
fDate
13-15 Feb. 2014
Firstpage
1
Lastpage
5
Abstract
This paper presents a comparative study between field oriented control (FOC) and direct torque control (DTC), two most popular control strategies for inverter fed interior permanent magnet synchronous motor (IPMSM) drives. The comparison is done in four switch three phase (FSTP) inverter scheme instead of six switch three phase (SSTP) inverter scheme. The FSTP inverter scheme is better than SSTP inverter scheme because of the reduction in price, switching losses and the complexity of the control board. The comparison is based on various conditions such as normal operating condition, sudden change in load torque, speed reversal and change in stator resistance. To validate the effectiveness of the drive systems, simulation is carried out in MATLAB environment. The simulation results and comparative study have been found quite satisfactory.
Keywords
machine vector control; permanent magnet motors; synchronous motor drives; torque control; DTC; FOC; FSTP inverter fed IPMSM drives; MATLAB environment; direct torque control; field oriented control; four switch three phase inverter; interior permanent magnet synchronous motor drives; load torque; six switch three phase inverter; speed reversal; stator resistance; Couplings; Inverters; Permanent magnet motors; Rotors; Stators; Switches; Torque; Direct torque control; field oriented control; four switch three phase inverter; interior permanent magnet synchronous motor; robustness;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Information and Communication Technology (EICT), 2013 International Conference on
Conference_Location
Khulna
Print_ISBN
978-1-4799-2297-0
Type
conf
DOI
10.1109/EICT.2014.6777825
Filename
6777825