DocumentCode
1185034
Title
Friction Factors for Forced Cooled Pipe-Type Electric Cable Systems
Author
Chern, S.Y. ; Chato, J.C.
Author_Institution
Planning Research Corporation Kennedy Space Center, Florida and University of Illinois
Issue
4
fYear
1979
fDate
7/1/1979 12:00:00 AM
Firstpage
1334
Lastpage
1336
Abstract
Friction factor curves were calculated for fully developed, laminar axial flows in underground electric cable systems with three cables inside a circular pipe. A finite element technique was used which is easily adaptable to irregular geometries.
Keywords
DH-HEMTs; Finite difference methods; Finite element methods; Friction; Geometry; Hydraulic diameter; Underground power cables; Urban planning; Viscosity; Wires;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1979.319333
Filename
4113623
Link To Document