DocumentCode :
1185395
Title :
Watthour Meter Accuracy on Integral-Cycle-Controlled Resistance Loads
Author :
Emanuel, A.E. ; Hynds, B.M. ; Levitsky, F.J.
Author_Institution :
Worcester Polytechnic Institute
Issue :
5
fYear :
1979
Firstpage :
1583
Lastpage :
1590
Abstract :
The change in performance of induction watthour meters when measuring integral-cycle-controlled resistance loads was studied. A simple mathematical model is used to explain the main cause for error. Test results for representative meters show that meters on integral cycle speed up, resulting in substantial positive errors. When mixed loads are monitored, the error becomes small and within commercially acceptable limits.
Keywords :
Circuit testing; Electrical resistance measurement; Error correction; Power conditioning; Steady-state; Switches; Thyristors; Velocity measurement; Voltage; Watthour meters;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1979.319473
Filename :
4113663
Link To Document :
بازگشت