DocumentCode
1187245
Title
Inter-bar currents in cage induction motors
Author
Williamson, S. ; Poh, C.Y.
Author_Institution
Sch. of Electr. & Electron. Eng., Univ. of Manchester, UK
Volume
152
Issue
5
fYear
2005
Firstpage
1106
Lastpage
1112
Abstract
Most induction motor analyses that allow for the presence of inter-bar currents are based on a rotor model in which the inter-bar currents are assumed to flow between adjacent pairs of bars. An alternative model is proposed in which the inter-bar currents flow into and around the rotor core. The validity of the new model is verified by means of measurements made on 54 rotors of identical design, which have been subjected to a range of treatments during manufacture to produce bar-to-bar resistances that differ by up to three orders of magnitude. It is shown that the new rotor model may readily be incorporated into existing analyses by redefining a single inter-bar resistance parameter. An alternative viewpoint of this is that the new rotor model redefines the relationship between the resistance parameter used in analytical models and the bar-to-bar resistance measured under test.
Keywords
bars; rotors; squirrel cage motors; analytical model; bar-to-bar resistance measurement; cage induction motor; inter-bar current; rotor model;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings -
Publisher
iet
ISSN
1350-2352
Type
jour
DOI
10.1049/ip-epa:20045147
Filename
1516800
Link To Document