DocumentCode :
1187255
Title :
Continuous-conduction-mode boost converter with reduced reverse-recovery loss
Author :
Do, H.-L.
Author_Institution :
PDP R&D Group, LG Electron. Inc., Gumi-|City, South Korea
Volume :
152
Issue :
5
fYear :
2005
Firstpage :
1113
Lastpage :
1118
Abstract :
A continuous-conduction-mode boost converter with reduced reverse-recovery loss is proposed. By utilising the auxiliary winding of the boost inductor, two additional rectifiers and an auxiliary inductor, the current decrease rates (di/dt) of the boost output rectifier and two additional rectifiers are slowed down to reduce the reverse-recovery loss. Experimental results for a 600 W power factor correction AC/DC boost converter at a constant switching frequency of 100 kHz are obtained to show the performance of the proposed converter. It is shown that a significant efficiency improvement is achieved.
Keywords :
AC-DC power convertors; power factor correction; rectifiers; switching convertors; 100 kHz; 600 W; AC/DC boost converter; auxiliary inductor; auxiliary winding; boost inductor; constant switching frequency; continuous-conduction-mode; power factor correction; rectifier; reverse-recovery loss reduction;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2352
Type :
jour
DOI :
10.1049/ip-epa:20050068
Filename :
1516801
Link To Document :
بازگشت