DocumentCode
1187617
Title
Crosstalk between microstrip transmission lines
Author
Hill, David A. ; Cavcey, Kenneth H. ; Johnk, Robert T.
Author_Institution
Electromagn. Fields Div., Nat. Inst. of Stand. & Technol., Boulder, CO, USA
Volume
36
Issue
4
fYear
1994
fDate
11/1/1994 12:00:00 AM
Firstpage
314
Lastpage
321
Abstract
Methods for prediction of crosstalk between microstrip transmission lines are reviewed and simplified for the weak-coupling case. Classical coupled transmission line theory is used for uniform lines, and potential and induced EMF methods are used for crosstalk between nonuniform lines. It is shown that the potential method is equivalent to classical coupled transmission line theory for the case of uniform lines. An experiment was performed for uniform coupled microstrip lines for frequencies from 50 MHz to 5 GHz, and good agreement between theory and measurement was obtained for both near- and far-end crosstalk
Keywords
crosstalk; electromagnetic induction; microstrip lines; transmission line theory; 50 MHz to 5 GHz; SHF; UHF; VHF; coupled transmission line theory; electromagnetic coupling; experiment; far-end crosstalk; induced EMF methods; measurement; microstrip transmission lines; near-end crosstalk; nonuniform lines; potential method; uniform lines; weak-coupling; Couplings; Crosstalk; Dielectric substrates; Frequency; Geometry; Microstrip; Multiconductor transmission lines; Transmission line matrix methods; Transmission line theory; Transmission lines;
fLanguage
English
Journal_Title
Electromagnetic Compatibility, IEEE Transactions on
Publisher
ieee
ISSN
0018-9375
Type
jour
DOI
10.1109/15.328861
Filename
328861
Link To Document