Title :
Ten Years of Operating Experience with a Remote Controlled Water Heater Load Management System at Detroit Edison
Author_Institution :
The Detroit Edison Company
fDate :
7/1/1980 12:00:00 AM
Abstract :
Detroit Edison has accumulated 10 years´ operating experience with a large-scale radio controlled electric water heater Load Management system. The limitations of the actual operating environment, both past and present, have greatly influenced Load Management strategies. Important lessons concerning cost effectiveness have been learned and must be applied to future. undertakings.
Keywords :
Clocks; Control systems; Heat engines; Large-scale systems; Load management; Radio control; Resistance heating; Shape control; Temperature control; Water heating;