Title : 
Bridge Circuit for Measuring Differences of Current or Voltage from a Preselected Value
         
        
        
            Author_Institution : 
Air Force Cambridge Research Laboratories, L. G. Hanscom Field, Bedford. Mass.
         
        
        
        
        
            fDate : 
6/1/1963 12:00:00 AM
         
        
        
        
            Abstract : 
A bridge circuit has been developed, using a Zener diode, which enables measurement of small changes in current or voltage from a preselected value. The circuit features increased sensitivity over a meter whose range includes the total current and is more easily used than a balanced bridge or potentiometer. The design equations are developed and the design procedure outlined for both the current and voltage difference measuring bridges, while a sample calculation is made for the current change measuring circuit. A bridge similar to that in the sample calculation was built and tested. The test circuit displayed less than 1 per cent nonlinearity of meter current vs change of input current for the design region of 460±5 ma. This shift was attributed to a slight heating of the Zener diode or a resistor at the higher test currents, but since the diode used in the test circuit had a smaller power rating than the type originally intended for use, it is not considered to be a serious limitation.
         
        
            Keywords : 
Bridge circuits; Circuit testing; Current measurement; Difference equations; Diodes; Heating; Impedance; Potentiometers; Resistors; Voltage measurement;
         
        
        
            Journal_Title : 
Instrumentation and Measurement, IEEE Transactions on
         
        
        
        
        
            DOI : 
10.1109/TIM.1963.4313325