DocumentCode :
1188617
Title :
A Gated Radiometer for Plasma Afterglow Study
Author :
Taft, W.C. ; Stotz, K.C. ; Holt, E.H.
Author_Institution :
Rensselaer Polytechnic Institute, Troy, N. Y.
Volume :
12
Issue :
2
fYear :
1963
Firstpage :
90
Lastpage :
96
Abstract :
In order to monitor the electron temperature during plasma afterglow experiments, a gated microwave radiometer has been developed. The radiometer differs from the usual Dicke type of radiometer in the input switching scheme and in the fact that a good time resolution is required. The radiometer to be described has a time resolution of one microsecond and a temperature sensitivity of about ten degrees Kelvin when measuring temperatures near room temperature. The response time when used with a repetitive afterglow is 20 seconds. Measurements of electron temperature in a decaying nitrogen plasma have been made duirng the initial 300 microseconds of the afterglow.
Keywords :
Delay; Electrons; Kelvin; Microwave radiometry; Nitrogen; Plasma measurements; Plasma temperature; Temperature measurement; Temperature sensors; Time measurement;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.1963.4313341
Filename :
4313341
Link To Document :
بازگشت