DocumentCode
118870
Title
Characterization of after-reflow misalignment on Head-in-Pillow defect in BGA assembly
Author
Chuan Chen ; Jian Cai ; Qian Wang ; Yuming Wang ; Guisheng Zou ; Zhengyu Zhao ; Chang Yong Park
Author_Institution
Inst. of Microelectron., Tsinghua Univ., Beijing, China
fYear
2014
fDate
12-15 Aug. 2014
Firstpage
1177
Lastpage
1180
Abstract
Head-in-Pillow (HiP) defect is a common issue in the Ball Grid Array (BGA) assembly. The defect is caused by several factors, individually or jointly, which includes warpage, misalignment, oxidation of the BGA ball, solder paste oxidation barrier capability, ect. The influence of before-reflow misalignment on HiP ratio(%HiP) has been studied. However, before-reflow misalignment can´t describe HiP defect accurately when other conditions changed. This paper focused on the influence of after-reflow misalignment on HiP ratio. Meanwhile, the influence of several factors like solder paste oxidation barrier capability, reflow time, weight of package(PKG) on after-reflow misalignment had also been investigated. Three kinds of reflow profiles were designed. Different oxidation barrier capability pastes were obtained with different soak times; and different reflow profiles were adjusted by setting different reflow time and soak time. In the experiment, all samples had the same before-reflow misalignment. Results showed that the HiP ratio could be predicted by comparing the after-reflow misalignment with the same solder paste oxidation barrier capability. There would be no or very low risk of HiP defect when the after-reflow misalignment was small. Solder paste oxidation barrier capability is a key factor that impact the after-reflow misalignment; low capability would cause the after-reflow misalignment to be much larger than that before reflow; and %HiP increased rapidly with the increase of after-reflow misalignment. That is, when increasing the solder paste oxidation barrier capability, the %HiP will be more and more insensitive to the change of after-reflow misalignment. With the increase of solder paste oxidation barrier capability and reflow time, the after-reflow misalignment will decrease; while it will increase with the increase of package (PKG) weight.
Keywords
ball grid arrays; reflow soldering; BGA assembly; HiP ratio; PKG; after-reflow misalignment characterization; ball grid array assembly; before-reflow misalignment; head-in-pillow defect; oxidation; package weight; reflow time; soak time; solder paste oxidation barrier capability; warpage; Educational institutions; Electronics packaging; Flip-chip devices; Hip; Oxidation; Soldering; Head-in-Pillow(HiP); after-reflow misalignment; oxidation barrier capability; reflow profile; weight of PKG;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronic Packaging Technology (ICEPT), 2014 15th International Conference on
Conference_Location
Chengdu
Type
conf
DOI
10.1109/ICEPT.2014.6922853
Filename
6922853
Link To Document