DocumentCode
1188788
Title
A New Method for the Prevention of Water and Sulfide Penetration and Deterioration of Cross-Linked Polyethylene (XLP) Insulated Submarine Power Cables
Author
Fukuda, T. ; Irie, S. ; Fujiki, S. ; Hisatsune, T.
Author_Institution
The Furukawa Electric Co., Ltd.
Issue
6
fYear
1980
Firstpage
2094
Lastpage
2101
Abstract
Based upon investigations reported herein, the major causes for the deterioration of rubber and plastics insulated submarine power cables have been established as water permeation and sulfide infection.
Keywords
Cable insulation; Conductors; Dielectrics and electrical insulation; Plastic insulation; Polyethylene; Power cables; Rubber; Trees - insulation; Underwater cables; Underwater vehicles;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1980.319851
Filename
4114046
Link To Document