  • Abstract
    A new method of measuring voltages across cavity gaps and deducing the cavity´s parallel resistance is discussed. The method is based on velocity modulation of a beam of monoenergetic charged particles (electrons) from a radioactive source. The change in the line spectra of an energy-selective particle detector (a semiconductor detector), when the particles pass through the gap, is used for calculating the cavity gap voltage. Combination with a measurement of the power dissipated in the cavity gives the value of the parallel resistance. A description is given of a practical arrangement together with experimental results.
  • Keywords
    Electrical resistance measurement; Electron beams; Energy measurement; Energy resolution; Pulse amplifiers; Pulse measurements; Q measurement; Solid scintillation detectors; Spectroscopy; Voltage;