DocumentCode
1189630
Title
A new method for the CCVT performance analysis using field measurements, signal processing and EMTP modeling
Author
Kojovic, Ljubomir ; Kezunovic, Mladen
Author_Institution
Cooper Power Syst., Franksville, WI
Volume
9
Issue
4
fYear
1994
fDate
10/1/1994 12:00:00 AM
Firstpage
1907
Lastpage
1915
Abstract
This paper presents the results of an EPRI study on development of a new method for coupling capacitor voltage transformer (CCVT) frequency response measurements from the secondary side. The method is especially suitable for field measurements since it does not require any internal CCVT disassembly or access to its individual components. It has been verified by performing the field measurements on actual CCVTs installed in a substation. The results were compared with the results obtained by carrying out the CCVT frequency response measurements on the same type of CCVTs in a laboratory and using the method of frequency response measurement from the primary side. The proposed method is easy to use and gives accurate results. The method may be used for the EMTP-based CCVT model development and the CCVT performance analysis
Keywords
digital simulation; frequency measurement; frequency response; potential transformers; power engineering computing; power transformer testing; signal processing; CCVT performance analysis; EMTP modeling; EMTP-based CCVT model development; coupling capacitor voltage transformer; field measurements; frequency response measurements; performance analysis; secondary side; signal processing; Capacitors; Circuits; EMTP; Frequency measurement; Frequency response; Performance analysis; Power measurement; Power system modeling; Signal processing; Transient analysis;
fLanguage
English
Journal_Title
Power Delivery, IEEE Transactions on
Publisher
ieee
ISSN
0885-8977
Type
jour
DOI
10.1109/61.329523
Filename
329523
Link To Document