    Design considerations for TEFC and explosion-proof three-phase ac induction motors in Arctic installations are discussed. Emphasized are applications in which ambient temperatures reach as low as -70°F and seismic forces are a factor, as along the Trans-Alaska Pipeline. Design technology for extreme low temperature is not new and has evolved from applications other than oil pipeline technology alone.
  • Keywords
    Arctic; Dielectric materials; Induction motors; Moisture; Petroleum; Pipelines; Resistance heating; Shafts; Space heating; Temperature;