DocumentCode
1190414
Title
Arctic Duty Motors
Author
Binns, Victor R. ; Cole, Ronald B.
Author_Institution
U.S. Electrical Motors, Milford, CT 06460.
Issue
1
fYear
1978
Firstpage
33
Lastpage
39
Abstract
Design considerations for TEFC and explosion-proof three-phase ac induction motors in Arctic installations are discussed. Emphasized are applications in which ambient temperatures reach as low as -70°F and seismic forces are a factor, as along the Trans-Alaska Pipeline. Design technology for extreme low temperature is not new and has evolved from applications other than oil pipeline technology alone.
Keywords
Arctic; Dielectric materials; Induction motors; Moisture; Petroleum; Pipelines; Resistance heating; Shafts; Space heating; Temperature;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/TIA.1978.4503486
Filename
4503486
Link To Document