Title :
Motor Surface Temperatures in Hazardous Areas
Author :
Bartheld, Robert G.
Author_Institution :
Siemens-Allis, Inc., Norwood, OH 45212.
fDate :
5/1/1978 12:00:00 AM
Abstract :
The temperature of motor surfaces is still a major concern of those operating equipment in hazardous (classified) areas. This surface temperature must be below the ignition temperature of the atmosphere under all possible operating conditions for Division 1 environments. Currently a 2150C maximum surface temperature is a must for a motor that can be operated in any Class I, Group D, Division 1 area without qualification. These lower temperatures are also causing a renewed interest in motor performance in Division 2 areas.
Keywords :
Atmosphere; Chemicals; Explosions; Flammability; Gases; Hazardous areas; Ignition; National electric code; Petroleum; Temperature distribution;
Journal_Title :
Industry Applications, IEEE Transactions on
DOI :
10.1109/TIA.1978.4503525