DocumentCode :
1191280
Title :
Point-Source Corona Current Distribution in an External Field
Author :
Collins, Leland F. ; Self, Sidney A. ; Shearer, Daniel D.
Author_Institution :
System Industries, Sunnyvale, CA.
Issue :
6
fYear :
1978
Firstpage :
506
Lastpage :
509
Abstract :
A simple expression is derived that describes the spreading of the current stream stemming from a point corona electrode situated in a uniform external field. The analysis assumes a uniform current density in the stream, constant mobility, and constant longitudinal field, and solves the equations of continuity and Poisson. Formula accuracy is determined to be about 10 percent by comparison with current density scans taken with a boundary probe.
Keywords :
Corona; Current density; Current distribution; Industry Applications Society; Ion beams; Laboratories; Needles; Poisson equations; Temperature; Voltage;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/TIA.1978.4503582
Filename :
4503582
Link To Document :