• DocumentCode
    1191280
  • Title

    Point-Source Corona Current Distribution in an External Field

  • Author

    Collins, Leland F. ; Self, Sidney A. ; Shearer, Daniel D.

  • Author_Institution
    System Industries, Sunnyvale, CA.
  • Issue
    6
  • fYear
    1978
  • Firstpage
    506
  • Lastpage
    509
  • Abstract
    A simple expression is derived that describes the spreading of the current stream stemming from a point corona electrode situated in a uniform external field. The analysis assumes a uniform current density in the stream, constant mobility, and constant longitudinal field, and solves the equations of continuity and Poisson. Formula accuracy is determined to be about 10 percent by comparison with current density scans taken with a boundary probe.
  • Keywords
    Corona; Current density; Current distribution; Industry Applications Society; Ion beams; Laboratories; Needles; Poisson equations; Temperature; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.1978.4503582
  • Filename
    4503582