DocumentCode
1191280
Title
Point-Source Corona Current Distribution in an External Field
Author
Collins, Leland F. ; Self, Sidney A. ; Shearer, Daniel D.
Author_Institution
System Industries, Sunnyvale, CA.
Issue
6
fYear
1978
Firstpage
506
Lastpage
509
Abstract
A simple expression is derived that describes the spreading of the current stream stemming from a point corona electrode situated in a uniform external field. The analysis assumes a uniform current density in the stream, constant mobility, and constant longitudinal field, and solves the equations of continuity and Poisson. Formula accuracy is determined to be about 10 percent by comparison with current density scans taken with a boundary probe.
Keywords
Corona; Current density; Current distribution; Industry Applications Society; Ion beams; Laboratories; Needles; Poisson equations; Temperature; Voltage;