DocumentCode
1191721
Title
A Systems Analysis of the Cesium Beam Atomic Clock
Author
Bell, C.M. ; Babitch, Daniel
Volume
17
Issue
2
fYear
1968
fDate
6/1/1968 12:00:00 AM
Firstpage
155
Lastpage
166
Abstract
A brief derivation of the transition probability for a two-state atomic system subjected to a phase modulated oscillatory perturbation is presented. This result is used to perform an analysis of a typical cesium beam atomic clock system utilizing a Ramsey (twin cavity) beam tube in order to determine optimum design parameters. It is shown theoretically and experimentally that the optimum modulation frequency for this type of system is higher than has previously been supposed. An additional feedback loop can be incorporated to nearly eliminate cavity phase error.
Keywords
Atomic beams; Atomic clocks; Electron tubes; Envelope detectors; Feedback loop; Frequency modulation; Microwave ovens; Phase detection; Phase frequency detector; Phase modulation;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1968.4313687
Filename
4313687
Link To Document