• DocumentCode
    1191922
  • Title

    Corona as a Means of Minimizing the Electric Current Surge from a DC High-Voltage Terminal

  • Author

    Inculet, Ion I. ; Webster, Alan R. ; Brash, Stewart W. ; Cheung, B.S.C.

  • Author_Institution
    Faculty of Engineering Science, University of Western Ontario, London, ON, Canada N6A 5B9.
  • Issue
    3
  • fYear
    1979
  • fDate
    5/1/1979 12:00:00 AM
  • Firstpage
    288
  • Lastpage
    290
  • Abstract
    It is often necessary to reduce the total energy released by an accidental spark discharge from a dc high-voltage terminal. The paper presents the results obtained with two experimental setups designed to investigate the effects of inserting a corona element in series with such terminals. The spark discharge onto a 23-cm diameter spherical probe was measured for the same terminal voltage with and without the corona element. Depending on the capacitances of the high-voltage circuit and of the corona element, and on the corona current-voltage characteristics, the reduction of the spark energy may reach one order of magnitude or more.
  • Keywords
    Capacitance; Circuits; Corona; Current; Current-voltage characteristics; Power supplies; Probes; Sparks; Surges; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.1979.4503654
  • Filename
    4503654