DocumentCode :
1191922
Title :
Corona as a Means of Minimizing the Electric Current Surge from a DC High-Voltage Terminal
Author :
Inculet, Ion I. ; Webster, Alan R. ; Brash, Stewart W. ; Cheung, B.S.C.
Author_Institution :
Faculty of Engineering Science, University of Western Ontario, London, ON, Canada N6A 5B9.
Issue :
3
fYear :
1979
fDate :
5/1/1979 12:00:00 AM
Firstpage :
288
Lastpage :
290
Abstract :
It is often necessary to reduce the total energy released by an accidental spark discharge from a dc high-voltage terminal. The paper presents the results obtained with two experimental setups designed to investigate the effects of inserting a corona element in series with such terminals. The spark discharge onto a 23-cm diameter spherical probe was measured for the same terminal voltage with and without the corona element. Depending on the capacitances of the high-voltage circuit and of the corona element, and on the corona current-voltage characteristics, the reduction of the spark energy may reach one order of magnitude or more.
Keywords :
Capacitance; Circuits; Corona; Current; Current-voltage characteristics; Power supplies; Probes; Sparks; Surges; Voltage;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/TIA.1979.4503654
Filename :
4503654
Link To Document :