DocumentCode
1192040
Title
Calibration of a Kerr Cell System for High-Voltage Pulse Measurements
Author
Cassidy, Esther C. ; Cones, Harold N. ; Wunsch, Donald C. ; Booker, Stanley R.
Volume
17
Issue
4
fYear
1968
Firstpage
313
Lastpage
320
Abstract
Several techniques for calibration of an electrooptical (Kerr cell) high-voltage pulse measuring system are described. Independent calibrations, without reference to pulse divider measurements, are achieved by application of a direct bias voltage to the Kerr cell. After calibration, experiments with voltages as high as 100 kV demonstrate reasonable agreement (to within 1 percent) between simultaneous Kerr cell and calibrated pulse divider measurements.
Keywords
Calibration; Electric variables measurement; Electrodes; Frequency measurement; Nonlinear optics; Optical modulation; Optical polarization; Optical pulses; Pulse measurements; Voltage measurement;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1968.4313725
Filename
4313725
Link To Document