• DocumentCode
    1192517
  • Title

    Starting Requirements of Pipeline Motors

  • Author

    Barr, Howard E.

  • Author_Institution
    U.S. Electrical Motors, Division of Emerson Electric Company, Prescott, AZ 86301.
  • Issue
    6
  • fYear
    1979
  • Firstpage
    625
  • Lastpage
    629
  • Abstract
    The design of an induction motor for pipelines is often controlled by the starting requirements, specifically by the starting current limitations imposed by the electrical utility. Designing the motor to meet across-the-line starting current limits means that full load running performance characteristics are compromised. Alternate starting methods can allow for optimizing the full load performance and result in a reduction of initial and operating costs.
  • Keywords
    Acceleration; Chemical industry; Conducting materials; Induction motors; Petroleum; Pipelines; Stators; Thermal stresses; Thermomechanical processes; Torque;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.1979.4503721
  • Filename
    4503721