• DocumentCode
    1192618
  • Title

    Linear Integrated Circuit Phase Meter

  • Author

    Ehret, Richard L. ; Wood, Lockett E. ; Thompson, M.C., Jr.

  • Volume
    18
  • Issue
    3
  • fYear
    1969
  • Firstpage
    157
  • Lastpage
    160
  • Abstract
    A precision phase meter with integrated circuits is described. Important features include variable sensitivity and automatic return toward midscale when the output approaches prescribed limits. The phase meter accepts inputs with frequencies from 10 to 100 kHz and with an amplitude range from 30 mV to 3 volts rms. The operational temperature range is from 0 to 50°C. The overall phase accuracy within these conditions is about 0.5°.
  • Keywords
    Analog integrated circuits; Frequency; Helium; Integrated circuit noise; Phase measurement; Pulse amplifiers; Pulse generation; Temperature distribution; Temperature sensors; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1969.4313792
  • Filename
    4313792