• DocumentCode
    1192888
  • Title

    Generator Selection for the Reliable Operation of Subsurface Centrifugal Pump Motors

  • Author

    Vandevier, Joseph E. ; Hocutt, Larry E.

  • Author_Institution
    Centrilift, Inc., Tulsa, OK 74101.
  • Issue
    1
  • fYear
    1980
  • Firstpage
    154
  • Lastpage
    160
  • Abstract
    Expanding applications for the use of submersible pumps for source or injection wells in the recovery of petroleum products require the use of engine-driven generator sets in those remote locations for which utility power is not available. Proper generator sizing for submersible pumping installation entails consideration of equipment setting depth, cable size, and the starting parameters of the motor. These unique system characteristics are dealt with and a method of calculating the generator capacity necessary for both proper starting and continuous operation are presented.
  • Keywords
    Induction generators; Induction motors; Oil insulation; Petroleum; Power cables; Power generation; Power transformer insulation; Pumps; Seals; Underwater vehicles;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.1980.4503761
  • Filename
    4503761