• DocumentCode
    1192903
  • Title

    A novel instrumentation amplifier with reduced magnitude and phase errors

  • Author

    Khan, Anwar A. ; Kumar, Arun

  • Author_Institution
    Dept. of Electr. Eng., King Saud Univ., Riyadh, Saudi Arabia
  • Volume
    40
  • Issue
    6
  • fYear
    1991
  • fDate
    12/1/1991 12:00:00 AM
  • Firstpage
    1035
  • Lastpage
    1038
  • Abstract
    A novel, simple, low-cost modification in the conventional instrumentation amplifier structure is suggested to minimize the magnitude and phase errors. Necessary analytical conditions are obtained to realize maximally flat magnitude and phase responses over a wide frequency range. The effect of the second pole of the op-amps on the circuit stability is presented. The proposed design has the advantage of flat magnitude and phase responses over an extended frequency range. Simulation and experimental results are given to support the theoretical conclusions
  • Keywords
    instrumentation amplifiers; operational amplifiers; circuit stability; error minimisation; instrumentation amplifier; magnitude errors; maximally flat magnitude; operational amplifier; phase errors; phase responses; simulation; Circuit simulation; Circuit stability; Data acquisition; Error analysis; Frequency; Instruments; Operational amplifiers; Read only memory; Resistors; Signal processing;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.119788
  • Filename
    119788