• DocumentCode
    1193576
  • Title

    Optimization of attenuation estimation in reflection for in vivo human dermis characterization at 20 MHz

  • Author

    Fournier, Céline ; Bridal, S. Lori ; Coron, Alain ; Laugier, Pascal

  • Author_Institution
    Lab. d´´Imagerie Parametrique, Univ. Paris VI, France
  • Volume
    50
  • Issue
    4
  • fYear
    2003
  • fDate
    4/1/2003 12:00:00 AM
  • Firstpage
    408
  • Lastpage
    418
  • Abstract
    In vivo skin attenuation estimators must be applicable to backscattered radio frequency signals obtained in a pulse-echo configuration. This work compares three such estimators: short-time Fourier multinarrowband (MNB), short-time Fourier centroid shift (FC), and autoregressive centroid shift (ARC). All provide estimations of the attenuation slope (/spl beta/, dB.cm/sup -1/.MHz/sup -1/); MNB also provides an independent estimation of the mean attenuation level (IA, dB.cm/sup -1/). Practical approaches are proposed for data windowing, spectral variance characterization, and bandwidth selection. Then, based on simulated data, FC and ARC were selected as the best (compromise between bias and variance) attenuation slope estimators. The FC, ARC, and MNB were applied to in vivo human skin data acquired at 20 MHz to estimate /spl beta//sub FC/, /spl beta//sub ARC/, and IA/sub MNB/, respectively (without diffraction correction, between 11 and 27 MHz). Lateral heterogeneity had less effect and day-today reproducibility was smaller for IA than for /spl beta/. The IA and /spl beta//sub ARC/ were dependent on pressure applied to skin during acquisition and IA on room and skin-surface temperatures. Negative values of IA imply that IA and /spl beta/ may be influenced not only by skin´s attenuation but also by structural heterogeneity across dermal depth. Even so, IA was correlated to subject age and IA, /spl beta//sub FC/, and /spl beta//sub ARC/ were dependent on subject gender. Thus, in vivo attenuation measurements reveal interesting variations with subject age and gender and thus appeared promising to detect skin structure modifications.
  • Keywords
    backscatter; biomedical ultrasonics; echo; optimisation; skin; ultrasonic absorption; ultrasonic reflection; ultrasonic scattering; 11 to 27 MHz; backscattered radio; in vivo human dermis characterization; optimization; pulse-echo configuration; reflection; skin attenuation estimators; Attenuation; Bandwidth; Dermis; Frequency estimation; Humans; In vivo; RF signals; Radio frequency; Reflection; Skin; Adult; Aged; Aging; Algorithms; Computer Simulation; Female; Forearm; Humans; Image Enhancement; Male; Middle Aged; Models, Biological; Models, Statistical; Quality Control; Radio Waves; Reproducibility of Results; Scattering, Radiation; Sensitivity and Specificity; Sex Factors; Signal Processing, Computer-Assisted; Skin; Skin Physiology; Ultrasonography, Doppler, Pulsed;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2003.1197964
  • Filename
    1197964