• DocumentCode
    1193597
  • Title

    Experimental spatial sampling study of the real-time ultrasonic pulse-echo BAI-mode imaging technique

  • Author

    Yin, Xiangtao ; Morris, Scott A. ; O´Brien, W.D.

  • Volume
    50
  • Issue
    4
  • fYear
    2003
  • fDate
    4/1/2003 12:00:00 AM
  • Firstpage
    428
  • Lastpage
    440
  • Abstract
    The ultrasonic pulse-echo backscattered amplitude integral (BAI)-mode imaging technique has been developed to inspect the seal integrity of hermetically sealed, flexible food packages. With a focused 17.3-MHz transducer acquiring radio frequency (RF) echo data in a static rectilinear stop-and-go pattern, this technique was able to reliably detect channel defects as small as 38 /spl mu/m in diameter and occasionally detect 6-/spl mu/m-diameter channels. This contribution presents our experimental spatial sampling study of the BAI-mode imaging technique with a continuous zigzag scanning protocol that simulates a real-time production line inspection method in continuous motion. Two transducers (f/2 17.3 MHz and f/3 20.3 MHz) were used to acquire RF echo data in a zigzag raster pattern from plastic film samples bearing rectilinear point reflector arrays of varying grid spacings. The average BAI-value difference (/spl Delta/BAI) between defective and intact regions and the contrast-to-noise ratio (CNR) were used to assess image quality as a function of three spatial sampling variables: transducer spatial scanning step size, array sample grid spacing, and transducer -6-dB pulse-echo focal beam spot size. For a given grid size, the /spl Delta/BAI and CNR degraded as scanning step size in each spatial dimension increased. There is an engineering trade-off between the BAI-mode image quality and the transducer spatial sampling. The optimal spatial sampling step size has been identified to be between one and two times the -6-dB pulse-echo focal beam lateral diameter.
  • Keywords
    seals (stoppers); ultrasonic imaging; ultrasonic materials testing; 17.3 MHz; RF echo; channel defect detection; contrast-to-noise ratio; focused transducer; food package; hermetic seal integrity; nondestructive inspection; plastic film; real-time ultrasonic pulse-echo backscattered amplitude integral mode imaging; spatial sampling; zigzag raster; Focusing; Hermetic seals; Image quality; Image sampling; Packaging; Protocols; Radio frequency; Sampling methods; Ultrasonic imaging; Ultrasonic transducers; Algorithms; Consumer Product Safety; Equipment Design; Equipment Failure Analysis; Food Contamination; Food Packaging; Image Enhancement; Quality Control; Sample Size; Sensitivity and Specificity; Transducers; Ultrasonography, Doppler, Pulsed;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2003.1197966
  • Filename
    1197966