Abstract
A simple technique for clock synchronization uses signals included in normal television transmissions as time markers. By use of automatic equipment built in the laboratory, it has been possible to make regular comparisons of time scales. Remote time laboratories can also be intercompared by this process. Accuracy of a fraction of a microsecond can be obtained easily. Numerical results of different experiments and comparisons with other methods are presented.