Title :
Monitor for integrity of seams in a shield enclosure
Author_Institution :
US Air Force Weapons Lab., Kirtland AFB, NM, USA
fDate :
8/1/1988 12:00:00 AM
Abstract :
A novel concept for measuring the performance of shield enclosures is considered. It allows for the presence of aperture-like faults at unknown positions over the shield enclosure. The aperture penetration is measured in a manner appropriate to bounding the response of internal equipment. The technique leads to the location of the fault as well
Keywords :
electromagnetic field theory; fault location; magnetic shielding; aperture penetration; aperture-like faults; fault location; performance measurement; seams; shield enclosure; Apertures; Conductors; Electromagnetic coupling; Electromagnetic fields; Electromagnetic measurements; Electromagnetic shielding; Electronic equipment; Magnetic moments; Monitoring; Wire;
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on