• DocumentCode
    1194799
  • Title

    An Evaluation of the Three-Voltmeter Method for AC Power Measurement

  • Author

    Marzetta, Louis A.

  • Volume
    21
  • Issue
    4
  • fYear
    1972
  • Firstpage
    353
  • Lastpage
    357
  • Abstract
    The accuracy and frequency response limitations in the present square-law responding laboratory wattmeters have promoted the search for alternate methods of ac power measurement using electronic instrumentation. The three-voltmeter method is based on an old principle of operation implemented by new analog circuitry. Results of the tests reported here show a precision of power calculation with 0.01 percent error at frequencies below 5 kHz. A unique test procedure is described for the comparison of the three-voltmeter device and a time-division multiplier wattmeter operating at zero power factor.
  • Keywords
    Circuits; Frequency measurement; Heating; Instruments; Laboratories; NIST; Power measurement; Testing; Voltage; Wattmeters;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1972.4314042
  • Filename
    4314042