DocumentCode :
1195431
Title :
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Author :
Wang, Guoxing ; Liu, Wentai ; Sivaprakasam, Mohanasankar ; Kendir, Gurhan Alper
Author_Institution :
Dept. of Electr. Eng., Univ. of California, Santa Cruz, CA, USA
Volume :
52
Issue :
10
fYear :
2005
Firstpage :
2109
Lastpage :
2117
Abstract :
Inductively coupled coil pair is the most common way of wirelessly transferring power to medical implants. However, the coil displacements and/or loading changes may induce large fluctuations in transmitted power into the implant if no adaptive control is used. In such cases, it is required to transmit excessive power to accommodate all the working conditions, which substantially reduces the power efficiency and imposes potential safety concerns. We have implemented a power transfer system with adaptive control technique to eliminate the power variations due to the loading or coupling coefficient changes. A maximum of 250mW power is transmitted through an optimized coil pair driven by Class-E power amplifier. Load shift keying is implemented to wirelessly transfer data back from the secondary to primary side over the same coil pair, with data rate of 3.3 kbps and packet error rate less than 10-5. A pseudo pulsewidth modulation has been designed to facilitate back data transmission along with forward power transmission. Through this back telemetry the system transmits the information on received power, back from implant to primary side. According to the data received, the system adjusts the supply voltage of the Class-E power amplifier through a digitally controlled dc-dc converter, thus varying the power sent to the implant. The key system parameters are optimized to ensure the stability of the closed-loop system. Measurements show that the system can transmit the ´just-needed´ power for a wide range of coil separation and/or loading conditions, with power efficiency doubled when compared to the uncompensated link.
Keywords :
DC power transmission; adaptive control; closed loop systems; digital control; power amplifiers; prosthetics; pulse width modulation; stability; telemetry; 250 mW; 3.3 kbit/s; adaptive control; adaptive transcutaneous power telemetry; back data transmission; back telemetry; biomedical implants; class-E power amplifier; closed loop system; coil displacements; coil pair; coil separation; dc-dc converter; digitally control; forward power transmission; inductive coupling; load shift keying; power transfer system; power variation; pseudo pulsewidth modulation; stability; uncompensated link; wireless power transfer; Adaptive control; Back; Coils; Employee welfare; Fluctuations; Implants; Power amplifiers; Pulse amplifiers; Safety; Telemetry; Back telemetry; closed-loop control; inductive link; power telemetry; reverse telemetry; transcutaneous power transfer;
fLanguage :
English
Journal_Title :
Circuits and Systems I: Regular Papers, IEEE Transactions on
Publisher :
ieee
ISSN :
1549-8328
Type :
jour
DOI :
10.1109/TCSI.2005.852923
Filename :
1519624
Link To Document :
بازگشت