Title :
Corona space charge development for combined alternating and direct voltage excitation
Author :
Rickard, D.A. ; Elayyan, H.S.B. ; Haddad, A. ; Waters, R.T.
Author_Institution :
Div. of Electr. Eng., Univ. of Wales Coll. of Cardiff, UK
fDate :
11/1/1994 12:00:00 AM
Abstract :
Corona in a coaxial test cage is investigated by tests and simulation for combined alternating and direct voltage excitations. The results of a test program which varied the polarity, magnitude and ratio R of the peak alternating to peak total voltage are examined in detail. Data measured include current, power loss, charge transport and optical output from the corona. A quantitative treatment is given by implementing and adapting an existing alternating current corona model. The improved understanding allows inferences to be made relevant to the performance of full-scale hybrid systems in which alternating and direct voltage circuits are built in close proximity
Keywords :
corona; space charge; AC circuits; DC circuits; charge transport; coaxial test cage; combined excitation; corona space charge; current; full-scale hybrid systems; inferences; magnitude; optical output; polarity; power loss; quantitative treatment; ratio R;
Journal_Title :
Science, Measurement and Technology, IEE Proceedings -
DOI :
10.1049/ip-smt:19941341