DocumentCode
1197715
Title
Induction Generator Applications for Petroleum and Chemical Plants
Author
Owen, Edward L. ; Griffith, Glenn R.
Author_Institution
Large Motor and Generator Department, General Electric Company
Issue
6
fYear
1983
Firstpage
1003
Lastpage
1013
Abstract
A 13 900-hp 1200-r/min induction machine has been applied as a motor/generator in a compressor-expander string associated with a fluid catalytic cracking (FCC) process. Power factor correction capacitors are connected at the terminals of the induction machine. The specific principles of application, as they apply to generator applications, of induction machines are reviewed. Mechanical design, overspeed, excitation, electrical and mechanical transients, and machine control are studied in detail.
Keywords
AC motors; Chemicals; FCC; Induction generators; Induction machines; Induction motors; Petroleum; Synchronous generators; Synchronous motors; Turbines;