An Improved Deadbeat Current Control Scheme With a Novel Adaptive Self-Tuning Load Model for a Three-Phase PWM Voltage-Source Inverter
Author
Mohamed, Yasser Abdel-Rady I. ; El-Saadany, Ehab F.
Author_Institution
Dept. of Electr. & Comput. Eng., Waterloo Univ., Ont.
Volume
54
Issue
2
fYear
2007
fDate
4/1/2007 12:00:00 AM
Firstpage
747
Lastpage
759
Abstract
In this paper, an improved deadbeat current control scheme with a novel adaptive self-tuning load model for a three-phase pulsewidth-modulated (PWM) voltage-source inverter is proposed. First, to achieve high-bandwidth current control characteristics, an improved deadbeat current controller with delay compensation is adopted. The compensation method forces the delay elements, which are caused by voltage calculation, PWM, and synchronous frame rotation, to be equivalently placed outside the closed-loop control system. Hence, their effect on the closed-loop stability is eliminated, and the current controller can be designed with a higher bandwidth. Second, to relax the parameter sensitivity issue of the deadbeat controller and to realize a control scheme with reduced sensors, a novel adaptive self-tuning load model is emerged in the control structure. The adaptive model is designed with low computational demand to estimate in real time the load parameters (R,L) and the back-electromotive-force voltage simultaneously. A unified solution to the present nonlinear estimation problem is presented by adopting a parallel observer structure. Furthermore, the adaptive model has the necessary phase advance of the estimated quantities, which compensates for the total system´s delay. Comparative evaluation results are presented to demonstrate the validity and effectiveness of the proposed control scheme
Keywords
PWM invertors; adaptive control; closed loop systems; compensation; control system synthesis; delays; electric current control; observers; self-adjusting systems; adaptive self-tuning load model; closed-loop control system; delay compensation; improved deadbeat current control; nonlinear estimation problem; parallel observer structure; parameter sensitivity; three-phase PWM voltage-source inverter; Adaptive control; Current control; Delay estimation; Force control; Load modeling; Programmable control; Pulse inverters; Pulse width modulation; Pulse width modulation inverters; Voltage control; Deadbeat current control; digital current control; p ulsewidth-modulated (PWM) inverters; robust adaptive estimation;
fLanguage
English
Journal_Title
Industrial Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0278-0046
Type
jour
DOI
10.1109/TIE.2007.891767
Filename
4118386
Link To Document