DocumentCode :
1199525
Title :
General Amplitude Relations for Transmission Lines with Unrestricted Line Parameters, Terminal Impedances, and Driving Point
Author :
King, Ronold
Author_Institution :
Cruft Laboratory and the Research Laboratory of Physics, Harvard University, Cambridge, Massachusetts
Volume :
29
Issue :
12
fYear :
1941
Firstpage :
640
Lastpage :
648
Abstract :
Subject to no other restrictions and approximations than those actually implied in the derivation of the transmission-line equations and their application to a terminated line, general expressions in simple form are derived for the current amplitude in, and the potential difference between, the two conductors of a uniform transmission line at any point along its extension. The terminal impedances are assumed to be perfectly general, and the line may be driven by a loosely coupled generator which maintains a sine-symmetrical, a cosine-symmetrical, or an unsymmetrical field along any section of the line. General resonance conditions are obtained and expressions written down for extreme values of the amplitudes. The special cases of low line damping and low over-all damping are considered.
Keywords :
Bridge circuits; Detectors; Frequency measurement; Impedance; Oscillators; Power transmission lines; Resonance; Transmission lines; UHF measurements; Wavelength measurement;
fLanguage :
English
Journal_Title :
Proceedings of the IRE
Publisher :
ieee
ISSN :
0096-8390
Type :
jour
DOI :
10.1109/JRPROC.1941.233637
Filename :
1694203
Link To Document :
بازگشت