• DocumentCode
    1201421
  • Title

    Study of recovery phenomena in a high-current pulse-triggered vacuum switch

  • Author

    Bauville, Gérard ; Delmas, Alain ; Haddad, Nabil ; Rioux, Christian

  • Author_Institution
    Lab. d´´Electrotech., Paris VI Univ., Orsay, France
  • Volume
    17
  • Issue
    5
  • fYear
    1989
  • fDate
    10/1/1989 12:00:00 AM
  • Firstpage
    781
  • Lastpage
    785
  • Abstract
    The recovery capacities of a triggered vacuum switch after the crossing of a 25-μs high-current pulse were investigated. The recovery time is less than 100 μs. An experiment was conducted with several electrodes with different gaps, and the influence of an axial magnetic field on the switch was studied. A diffuse arc mode was achieved, making possible a commutation power as high as 109 VA
  • Keywords
    plasma switches; plasma transport processes; 100 ps; 25 ps; axial magnetic field; commutation power; diffuse arc mode; high-current pulse-triggered vacuum switch; recovery phenomena; Capacitors; Cathodes; Circuit testing; Coils; Electrodes; Energy storage; Inductors; Magnetic fields; Switches; Voltage;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/27.41203
  • Filename
    41203