• DocumentCode
    1201562
  • Title

    Electrooptical Blood-Spot Detection in Intact Eggs

  • Author

    Gielen, Robert M.A.M. ; de Jong, Leo P. ; Kerkvliet, Harry M.M.

  • Volume
    28
  • Issue
    3
  • fYear
    1979
  • Firstpage
    177
  • Lastpage
    183
  • Abstract
    An electrooptical measuring device has been developed for detecting blood spots in intact eggs based on the selective absorption of hemoglobin. The detection system performs a ratio measurement at two wavelengths with an accuracy and stability within 1 percent over a dynamic range of three decades of absolute egg transmittance values. Because of the very low transmittance level much care has been given to stray- and background-light suppression The detection results re substantially independent of electrooptical transfer vriations System design includes economical factors and is partly devoted to a 12 row conveyor belt system with a cycling time of 1 s. The system discriminating sensitivity in selective absorption can be adapted to the natural scatter in the spectral properties of eggs.
  • Keywords
    Absorption; Blood; Detectors; Dynamic range; Electrooptic devices; Low earth orbit satellites; Optical signal processing; Performance evaluation; Stability; Wavelength measurement;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1979.4314801
  • Filename
    4314801