Abstract :
A method for determining the essential parameters of the aorta, namely the geometric taper, area, hoop elasticity, and effective loss factor, from in vivo pressure measurements is presented. A nonuniform hybrid model, having both geometric and elastic taper and terminated in a reflectionless impedance at the femoral bifurcation, is utilized.
Keywords :
Bifurcation; Biomedical monitoring; Blood pressure; Catheters; Dogs; In vivo; Parameter estimation; Pressure measurement; Transducers; Transfer functions; Animals; Aorta; Blood Pressure Determination; Chickens; Dogs; Mathematics; Methods;