• DocumentCode
    1202575
  • Title

    High-Temperature High-Pressure Electrostatic Precipitator Electrical Characterization and Collection Efficiency

  • Author

    Rinard, George ; Rugg, Donald E. ; Yamamoto, Toshiaki

  • Author_Institution
    Denver Research Institute, University of Denver, P.O. Box 10127, Denver, CO 80210.
  • Issue
    1
  • fYear
    1987
  • Firstpage
    114
  • Lastpage
    119
  • Abstract
    To evaluate the operation of an electrostatic precipitator (ESP) at pressurized fluidized bed combustor (PFBC) conditions, the Denver Research Institute (DRI) high-pressure high-temperature test electrostatic precipitator was used to measure the electrical operating characteristics and collection efficiencies for an operating pressure of 640 kPa (6.4 bar). Electrical operating characteristics were measured for three different electrodes, and collection efficiency was measured for one of these electrodes, with both negative and positive corona and temperatures near 870°C (1600°F). Collection efficiencies were also measured for negative corona at temperatures of 743° and 821°C (1370° and 1510°F). A description of the precipitator system test conditions and test results is given below.
  • Keywords
    Corona; Electric variables measurement; Electrodes; Electrostatic measurements; Electrostatic precipitators; Fluidization; Power generation; Sampling methods; System testing; Temperature;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.1987.4504875
  • Filename