• DocumentCode
    1203663
  • Title

    Effects of imbalances and nonlinear loads on the voltage balance of a neutral-point-clamped inverter

  • Author

    Pou, J. ; Boroyevich, D. ; Pindado, R.

  • Author_Institution
    Dept. of Electron. Eng., Tech. Univ. of Catalonia, Spain
  • Volume
    20
  • Issue
    1
  • fYear
    2005
  • Firstpage
    123
  • Lastpage
    131
  • Abstract
    The effects of linear imbalances and nonlinear loads on the voltage balance of the neutral-point-clamped converter are described in this paper. The study reveals that a negative sequence of output currents (linear imbalance) may produce additional low-frequency oscillations to the neutral-point voltage. Similar consequences are produced by odd-order current harmonics from a nonlinear load, while even-order harmonics can cause the neutral-point voltage to shift. Furthermore, the second, fourth, and eighth output current harmonics might produce instability to the neutral-point voltage. The second and fourth harmonics are the worst components. The maximum amplitudes of these harmonics superposed to the current fundamentals that the system can tolerate are described. Simulated and experimental examples are presented.
  • Keywords
    harmonics; invertors; power convertors; current harmonics; imbalance load; linear imbalance; neutral-point balance; neutral-point-clamped inverter; nonlinear load; space vector modulation; three-level inverter; voltage balance; Bridge circuits; Capacitors; Inverters; Mathematical model; Power electronics; Power engineering and energy; Power quality; Renewable energy resources; Switches; Voltage; Linear imbalances; nearest vectors; neutral-point balance; nonlinear loads; space-vector modulation; three-level inverter;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2004.839823
  • Filename
    1377400