DocumentCode
1204170
Title
A Combined Transformer Bridge for Precise Comparison of Inductance with Capacitance
Author
Muciek, Andrzej
Volume
32
Issue
3
fYear
1983
Firstpage
419
Lastpage
423
Abstract
A combined transformer bridge, composed of two alternately balanced transformer bridges, designed for precise comparison of inductance with capacitance standards has been analyzed. A number of possible sources of error have been studied and experimentally examined in a constructed model of the combined bridge. The experimental results confirmed an ability to measure inductance in reference to capacitance with an accuracy up to 10 parts per million (ppm) in the frequency band 0.16-2 kHz.
Keywords
Bridge circuits; Capacitance measurement; Capacitors; Frequency measurement; Impedance; Inductance measurement; Inductors; Measurement standards; Resistors; Switches;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1983.4315098
Filename
4315098
Link To Document