DocumentCode :
1204183
Title :
Test results of an apparatus for calorimetric measurement of AC losses in superconductors
Author :
Eikelboom, J.A.
Author_Institution :
Netherlands Energy Res. Found. ECN, Petten, Netherlands
Volume :
28
Issue :
1
fYear :
1992
fDate :
1/1/1992 12:00:00 AM
Firstpage :
817
Lastpage :
821
Abstract :
A description is given of a novel method to measure calorimetrically AC losses in superconducting samples. The boil-off gas is stored below the liquid helium level in a measuring tube. Losses in the range of 1 mW up to 100 mW can be measured with an accuracy of 3%. Results of measurements of AC losses in superconducting wires are presented. In contrast to measurements with gas-flow meters, there is a negligible background signal and an excellent reproducibility as all measurements are performed at the temperature of boiling helium
Keywords :
calorimetry; loss measurement; superconducting cables; AC losses; background signal; boil-off gas; calorimetric measurement; reproducibility; superconducting wires; Calibration; Energy measurement; Fluid flow; Glass; Helium; Loss measurement; Superconducting filaments and wires; Superconducting magnets; Superconductivity; Testing;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.120003
Filename :
120003
Link To Document :
بازگشت