• DocumentCode
    1204666
  • Title

    A Heterodyne Low-Level Signal Phase Meter Operating over 1 MHz to 300 MHz

  • Author

    Dziadowiec, Alexandre ; Lescure, Marc ; Boucher, Jacques

  • Volume
    33
  • Issue
    1
  • fYear
    1984
  • fDate
    3/1/1984 12:00:00 AM
  • Firstpage
    55
  • Lastpage
    58
  • Abstract
    After giving a brief summary of the main devices allowing the measurement of phase shifts between two sine signals in the approximate range 1 Hz-1 GHz, we propose a new apparatus for measuring phase shift. The principle of this apparatus uses a heterodyne technique in association with a phase-locked loop which brings about frequency translation of the measured signals. The intermediate frequency which is obtained is small with respect to the frequencies studied conveying a high degree of selectivity to the apparatus. This allows measurements to be made on signal with noise or low-level signal while also maintaining good accuracy. For a system operating from 1-300 MHz, we have obtained phase linearity of ± 1°, resolution of 0.1°. In obtaining the accuracy of ± 5°, the sensitivity is -86 dBm in the 1-30-MHz frequency range; with 300 MHz the sensitivity reached is -68 dBm.
  • Keywords
    Assembly; Circuits; Clocks; Frequency conversion; Frequency measurement; Instruments; Phase measurement; Time measurement; Timing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1984.4315153
  • Filename
    4315153