DocumentCode
1204855
Title
Practical Method for Calculating the Thermal or Driving Point of Lines: Grounding Applications
Author
Ovide, Benito Alvarez ; Diaz, Susana Beatriz
Volume
33
Issue
2
fYear
1984
fDate
6/1/1984 12:00:00 AM
Firstpage
130
Lastpage
134
Abstract
The different problems involved in the design and techniques to establish earth grounding and reference plane systems that are compatible with requirements of measurement standards are discussed considering transmission line theory particularly when the reference plane must be electrically far from the earth. A solution for several cases is outlined.
Keywords
Breakdown voltage; Cable shielding; Distributed parameter circuits; Frequency; Grounding; Impedance; Laboratories; Measurement standards; Power cables; Transmission line theory;