• DocumentCode
    1205409
  • Title

    Measurement Principles of the Reactive Current RMS Value and the Load Susceptance for Harmonic Frequency Meters

  • Author

    Czarnecki, Leszek S.

  • Issue
    1
  • fYear
    1985
  • fDate
    3/1/1985 12:00:00 AM
  • Firstpage
    14
  • Lastpage
    17
  • Abstract
    The current of a nonsinusoidal source applied to a nonresistive load contains a reactive component ir which can be decreased or even wholly compensated by a shunt reactance 1-port of parameters related directly to the load susceptances for harmonic frequencies Bn?? The reactive current rms value measurement is necessary for evaluation of the possibility of the source apparent power minimization, and the load susceptance measurement is necessary for the compensating equipment design. This paper presents the measurement principles for measuring these quantities.
  • Keywords
    Admittance; Current measurement; Delay effects; Distortion measurement; Frequency measurement; Power harmonic filters; Power measurement; Power system harmonics; Shunt (electrical); Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1985.4315247
  • Filename