DocumentCode
1205409
Title
Measurement Principles of the Reactive Current RMS Value and the Load Susceptance for Harmonic Frequency Meters
Author
Czarnecki, Leszek S.
Issue
1
fYear
1985
fDate
3/1/1985 12:00:00 AM
Firstpage
14
Lastpage
17
Abstract
The current of a nonsinusoidal source applied to a nonresistive load contains a reactive component ir which can be decreased or even wholly compensated by a shunt reactance 1-port of parameters related directly to the load susceptances for harmonic frequencies Bn?? The reactive current rms value measurement is necessary for evaluation of the possibility of the source apparent power minimization, and the load susceptance measurement is necessary for the compensating equipment design. This paper presents the measurement principles for measuring these quantities.
Keywords
Admittance; Current measurement; Delay effects; Distortion measurement; Frequency measurement; Power harmonic filters; Power measurement; Power system harmonics; Shunt (electrical); Voltage;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1985.4315247
Filename
4315247
Link To Document