Title :
Ion Trap as a Frequency Standard Measurement of Ba+ HFS Frequency Fluctuations
Author :
Knab, Holger ; Niebling, Klaus-D. ; Werth, Gunter
fDate :
6/1/1985 12:00:00 AM
Abstract :
The 8-GHz "field independent" F = 1, mF = 0 to F = 2, mF = 0 ground level Zeeman transition frequency in 137Ba+ ions has been compared with a commercial Cs beam standard. About 10+ ions were stored in a RF quadrupole trap for several hours and cooled by He buffer gas. Hyperfine pumping was achieved by a pulsed tunable dye laser and the transition between the Zeeman sublevels was induced by a microwave signal locked to the primary frequency standard. The transition was observed via changes in the ionic fluorescence intensity. The observed frequency fluctuations ??v/v of < 2 ?? 10-12 over a 5-h measurement period are compatible with the specified fluctuations of the reference. Possible sources of frequency shifts were. analyzed and found to be controllable within the precision set by the atomic frequency reference.
Keywords :
Buffer storage; Fluctuations; Frequency measurement; Laser beams; Laser excitation; Measurement standards; Optical pulses; Radio frequency; Tunable circuits and devices;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
DOI :
10.1109/TIM.1985.4315314