DocumentCode
1206461
Title
Instantaneous Frequency Measurements of Neural Events: Application of Non-Uniformly Distributed RC Line
Author
Gagné, Simon ; Poussart, Denis
Author_Institution
Department of Electrical Engineering and Center of Bionics, Laval University, Quebec, P. Q., Canada.
Issue
1
fYear
1976
Firstpage
16
Lastpage
22
Abstract
The display of instantaneous frequency as a function of real time (Frequencygram) is an efficient type of data presentation in studies of point processes such as neuronal events. This paper surveys and compares various methods for its analog implementation.
Keywords
Councils; Delay; Digital simulation; Displays; Frequency measurement; Higher order statistics; Information analysis; Information processing; Instruments; Nervous system; Computers, Analog; Humans; Nervous System Physiology; Online Systems; Time Factors;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.1976.324610