• DocumentCode
    1206709
  • Title

    Optical time domain reflectometry in optical transmission lines containing in-line Er-doped fiber amplifiers

  • Author

    Sato, Yoshiaki ; Aoyama, Koh-ichi

  • Author_Institution
    NTT Transmission Syst. Lab., Kanagawa, Japan
  • Volume
    10
  • Issue
    1
  • fYear
    1992
  • fDate
    1/1/1992 12:00:00 AM
  • Firstpage
    78
  • Lastpage
    83
  • Abstract
    Optical time domain reflectometry (OTDR) in an optical transmission line containing in-line Er-doped fiber amplifiers is investigated. The proposed Er-doped fiber amplifiers are based on optical circulators, which support both OTDR and digital signal transmission. The measurable limit of OTDR fault location in optical transmission lines containing in-line amplifiers is discussed. Fault location and 1.8-Gb/s digital signal transmission are demonstrated in a 316.9 km, optical transmission line constructed with three in-line Er-doped fiber amplifiers
  • Keywords
    erbium; fault location; fibre lasers; optical communication equipment; optical links; optical testing; time-domain reflectometry; 1.8 Gbit/s; 316.9 km; OTDR fault location; OTDR signal transmission; digital signal transmission; in-line Er-doped fiber amplifiers; measurable limit; optical circulators; optical time domain reflectometry; optical transmission lines; Erbium-doped fiber amplifier; Fault location; Isolators; Optical attenuators; Optical fiber amplifiers; Optical pumping; Pulse amplifiers; Reflectometry; Stimulated emission; Transmission lines;
  • fLanguage
    English
  • Journal_Title
    Lightwave Technology, Journal of
  • Publisher
    ieee
  • ISSN
    0733-8724
  • Type

    jour

  • DOI
    10.1109/50.108740
  • Filename