• DocumentCode
    1207522
  • Title

    Use of Ferroelectrics for Gamma-Ray Dosimetry

  • Author

    Hester, D.L. ; Glower, D.D. ; Overton, L.J.

  • Author_Institution
    Sandia Corporation, Albuquerque, New Mexico
  • Volume
    11
  • Issue
    5
  • fYear
    1964
  • Firstpage
    145
  • Lastpage
    154
  • Abstract
    A gamma-ray dosimeter employing a poled ferroelectric as the transducer element has been studied. Irradiation with gamma rays causes a release of charge by the ferroelectric element. The magnitude of the charge released has been determined experimentally to vary linearly with gamma-ray dose. The current in a shunting resistor with no external voltage applied varies linearly with gamma-ray dose rate. A constant of proportionality of 10-12 coul per rad (H2O) per cm2 of electroded ferroelectric surface has been measured for polycrystalline Pb(Zr.65 Ti.35)O3 + 1 w% Nb2O5 irradiated in the Sandia Pulsed Reactor. The contribution to the charge release from the neutron irradiation has been determined experimentally to be negligible. Irradiation in the 0.6 Mvp flash X-ray also produces a linear relationship between current and gamma-ray dose rate. A similar release of charge has been observed in poled ceramic barium titanate.
  • Keywords
    Dosimetry; Ferroelectric materials; Gamma rays; Inductors; Neutrons; Pulse measurements; Resistors; Transducers; Voltage; Water;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS2.1964.4315485
  • Filename
    4315485