DocumentCode
1207790
Title
A Dual Function Gamma Monitor
Author
Connally, R.E.
Author_Institution
General Electric Co., Hanford Atomic Products Operation, Richland, Wash.
Volume
3
Issue
2
fYear
1956
fDate
3/1/1956 12:00:00 AM
Firstpage
28
Lastpage
31
Abstract
A thallium-activated sodium iodide gamma monitor is described which utilizes both the ac and dc components of the anode current of a multiplier phototube. The dc component serves to monitor over a range of 104 the gross gamma activity of selected points in a solvent extraction plant for the processing of spent nuclear fuel. From the ac component a gamma energy analysis is obtained over an activity range of 102. The ac component also serves as a monitor on the multiplier phototube gain adjustment. The characteristics of the gamma monitor system are discussed.
Keywords
Anodes; Gamma ray detection; Gamma ray detectors; Monitoring; Nuclear fuels; Photoelectricity; Solid scintillation detectors; Solvents; Spectroscopy; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IRE Transactions on
Publisher
ieee
ISSN
0096-2015
Type
jour
DOI
10.1109/TNS2.1956.4315522
Filename
4315522
Link To Document