Title :
A Dual Function Gamma Monitor
Author_Institution :
General Electric Co., Hanford Atomic Products Operation, Richland, Wash.
fDate :
3/1/1956 12:00:00 AM
Abstract :
A thallium-activated sodium iodide gamma monitor is described which utilizes both the ac and dc components of the anode current of a multiplier phototube. The dc component serves to monitor over a range of 104 the gross gamma activity of selected points in a solvent extraction plant for the processing of spent nuclear fuel. From the ac component a gamma energy analysis is obtained over an activity range of 102. The ac component also serves as a monitor on the multiplier phototube gain adjustment. The characteristics of the gamma monitor system are discussed.
Keywords :
Anodes; Gamma ray detection; Gamma ray detectors; Monitoring; Nuclear fuels; Photoelectricity; Solid scintillation detectors; Solvents; Spectroscopy; Voltage;
Journal_Title :
Nuclear Science, IRE Transactions on
DOI :